Buffer vessels for closed hot water heating systems with a welded-in straight-tube heat exchanger for the hydraulically separated integration of additional heating systems (e.g. the combination of solid fuel boilers with solar systems or similar). Robust and installation-friendly design. Equipped with various sensor connections for the individual adjustment of the temperature control. Foot height adjustment for quick and safe alignment. Powder coated exterior, uncoated interior.
General information
- Permissible positive operating pressure: Buffer vessel/heating coil 3/10 bar.
- Permissible operating temperature: Buffer vessel/heating coils 95/110 °C (368/383 K).
Storage water heater insulation (to be ordered separately, see storage water heater accessories):
- Thermal insulation: 100 mm fleece insulation with a polystyrene outer layer as an installation-friendly kit.
- Standard insulation colours: white (RAL 9010) and white aluminium (RAL 9006).
- Fleece insulation complies with fire protection class B2 according to DIN 4102.

Type | Nominal capacity [l] | Dimensions * | Heating surface ** [m2] | Weight [kg] | Order no. | ||
Ø [mm] | H [mm] | Tilt height [mm] | |||||
SP-2WT 600 | 600 | 650 | 2050 | 2100 | 1,5 / 2,0 | 146 | 419353 |
SP-2WT 750 | 750 | 790 | 1800 | 1850 | 1,5 / 2,1 | 156 | 419354 |
SP-2WT 850 | 850 | 790 | 1950 | 2000 | 2,0 / 2,3 | 205 | 419355 |
SP-2WT 1000 (Ø790) | 1000 | 790 | 2200 | 2250 | 2,2 / 2,7 | 245 | 419356 |
SP-2WT 1000 (Ø850) | 1000 | 850 | 2000 | 2050 | 2,2 / 2,7 | 243 | 419357 |
SP-2WT 1200 | 1200 | 850 | 2250 | 2300 | 2,6 / 2,9 | 261 | 419358 |
SP-2WT 1500 | 1500 | 1000 | 2320 | 2380 | 2,8 / 3,2 | 306 | 419359 |
SP-2WT 2000 | 2000 | 1100 | 2350 | 2400 | 3,5 / 5,0 | 396 | 419360 |
* Dimensions excluding insulation.
** Upper/lower heating surface.
Type | System connections | Distance from floor to connections | ||||||||
A [mm] | B [mm] | C [mm] | D [mm] | E [mm] | F [mm] | K [mm] | L [mm] | M [mm] | ||
SP-2WT 600 | 8 | 180 | 280 | 730 | 880 | 980 | 1240 | 1280 | 1680 | 1830 |
SP-2WT 750 | 8 | 270 | 370 | 690 | 890 | 940 | 1060 | 1100 | 1420 | 1520 |
SP-2WT 850 | 8 | 270 | 370 | 740 | 920 | 970 | 1090 | 1200 | 1570 | 1670 |
SP-2WT 1000 (Ø790) | 8 | 270 | 370 | 820 | 1010 | 1095 | 1210 | 1370 | 1820 | 1920 |
SP-2WT 1000 (Ø850) | 8 | 305 | 405 | 790 | 1005 | 1075 | 1125 | 1220 | 1605 | 1705 |
SP-2WT 1200 | 8 | 305 | 405 | 855 | 1045 | 1195 | 1295 | 1405 | 1855 | 1955 |
SP-2WT 1500 | 8 | 340 | 440 | 890 | 1040 | 1230 | 1370 | 1440 | 1890 | 1990 |
SP-2WT 2000 | 8 | 350 | 450 | 900 | 1200 | 1310 | 1380 | 1450 | 1900 | 2000 |
Specifications | SP-2WT 600 – 2000 | |||||||
600 | 750 | 850 | 1000 Ø790 | 1000 Ø850 | 1200 | 1500 | 2000 | |
Total heat loss (EN 12897) [W] | 147,4 | 156,3 | 164,9 | 171,6 | 175,7 | 191 | 226 | 295,3 |
Energy label | n/a | n/a | n/a | n/a | n/a | n/a | n/a | n/a |
n/a = not applicable.
Accessories