If sufficient space is available, the liquid gas vessel can be installed at a suitable location. A simple, prefabricated concrete slab is adequate as a base.

General information

  • Max. permissible pressure PS:  15.6 bar
  • Maximum filling:  85 %
  • Volume V:  see table
  • Type of gas:  butane/propane
  • Min./max. permissible temperature TS:  -40/+40

All liquid gas tanks are equipped with:

Fill valve
Liquid discharge valve
Gas discharge valve with
  • Manual outlet valve with sounding pipe
  • Overfill protection
  • Pressure gauge
  • Test connection
Safety valve
Level indicator
Nominal capacity 
Litre
A Ø
[mm]
B
[mm]
C
[mm]
D
[mm]
E
[mm]
F
[mm]
G
[mm]
Weight
[kg]
Order no.
RAL 9010 white
Order no.
RAL 6019 green
99080022251420450950112015026004020-901004020-6019
1600125015706878001400157015040004018-901004018-6019
27001250248016008001400157015053004021-901004021-6019
48501250428020008001400157015080004022-901004022-6019
6400 lateral12505500350080014001570150110004023-901004023-6019
6400 central12505500350080014001570150110004024-901004024-6019